Document Type
Article
Publication Date
1-2009
Abstract
There is a growing prevalence of robotic systems for surgical laparoscopy. We previously developed quantitative measures to assess robotic surgical proficiency, and used augmented feedback to enhance training to reduce applied grip force and increase speed. However, there is also a need to understand the physiological demands of the surgeon during robotic surgery, and if training can reduce these demands. Therefore, the goal of this study was to use clinical biomechanical techniques via electromyography (EMG) to investigate the effects of real-time augmented visual feedback during short-term training on muscular activation and fatigue. Twenty novices were trained in three inanimate surgical tasks with the da Vinci Surgical System. Subjects were divided into five feedback groups (speed, relative phase, grip force, video, and control). Time- and frequency-domain EMG measures were obtained before and after training. Surgical training decreased muscle work as found from mean EMG and EMG envelopes. Grip force feedback further reduced average and total muscle work, while speed feedback increased average muscle work and decreased total muscle work. Training also increased the median frequency response as a result of increased speed and/or reduced fatigue during each task. More diverse motor units were recruited as revealed by increases in the frequency bandwidth post-training. We demonstrated that clinical biomechanics using EMG analysis can help to better understand the effects of training for robotic surgery. Real-time augmented feedback during training can further reduce physiological demands. Future studies will investigate other means of feedback such as biofeedback of EMG during robotic surgery training.
Journal Title
Journal of Biomechanics
Volume
42
Issue
1
First Page
71
Last Page
76
Recommended Citation
Judkins, Timothy N.; Oleynikov, D.; and Stergiou, Nikolaos, "Electromyographic response is altered during robotic surgical training with augmented feedback" (2009). Journal Articles. 157.
https://digitalcommons.unomaha.edu/biomechanicsarticles/157
Comments
NOTICE: this is the author’s version of a work that was accepted for publication in Journal of Biomechanics. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Journal of Biomechanics, Vol. 42, Issue 1 (January 2009) http://dx.doi.org/10.1016/j.jbiomech.2008.09.039.