Document Type
Article
Publication Date
3-2-2026
Abstract
Purpose Peripheral artery disease (PAD) predominantly affects the lower extremities, where complex biomechanical deformations during limb flexion contribute to disease progression and treatment failure. While human and cadaver studies have characterized these deformations, preclinical device testing requires large-animal models that replicate human arterial anatomy and biomechanics. Swine are commonly used, yet their biomechanical comparability to humans remains poorly defined. Methods We performed a detailed morphometric and biomechanical analysis of the external iliac (EIA), superficial femoral (SFA), and popliteal (PA) arteries in 20 Yucatan and 16 domestic swine using computed tomography angiography. Arteries were evaluated in straight and flexed limb postures to assess diameters, lengths, axial compression, tortuosity, bending angles, and inscribed sphere radii. Breed-specific effects of age and weight were also analyzed. Results Porcine arterial dimensions closely matched human lower extremity vessels. EIA diameters (4.9–7.2 mm) corresponded to human SFA, porcine SFA (4.1–5.9 mm) approximated human PA, and porcine PA (3.0–4.7 mm) resembled human tibial arteries. Segment lengths supported use of multiple devices. Flexion induced 12–33% axial compression, mimicking worst-case human scenarios. Tortuosity increased distally, and bending characteristics in porcine PAs aligned with human data. In Yucatan swine, vessel diameters were stable with age and weight, while domestic swine exhibited greater variability. Flexion-induced compression and tortuosity were not influenced by age or weight. Conclusion Swine are well-suited for modeling the geometry and biomechanics of human lower extremity arteries. Their anatomical compatibility and ability to replicate physiologic deformations make them valuable models for preclinical testing of PAD therapies and vascular devices.
DOI
https://doi.org/10.1007/s10439-026-04066-0
Journal Title
Annals of Biomedical Engineering
Volume
54
First Page
2600
Accessibility Statement
PDF passed Adobe Accessibility Checker prior to upload.
Last Page
2613
Recommended Citation
Batista de Oliveira, Barbara; Heinis, Frazer; Desyatova, Anastasia; MacTaggart, Jason; and Kamenskiy, Alexey, "Biomechanical Characterization of Porcine Lower Limb Arteries for Preclinical Evaluation of Peripheral Vascular Devices" (2026). Journal Articles. 420.
https://digitalcommons.unomaha.edu/biomechanicsarticles/420
Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 License.
Files over 3MB may be slow to open. For best results, right-click and select "save as..."
Included in
Funded by the University of Nebraska at Omaha Open Access Fund
Comments
This article was published open access using the library's Springer open access publishing agreement.